set pwa maxrequest
19-70 Authentication and Authorization Configuration
Defaults
Ifportstringisnotspecified,quietperiodwillbesetforallports.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetthePWAquietperiodto30secondsforportsge.1.57:
B2(su)->set pwa quietperiod 30 ge.1.5-7
set pwa maxrequest
Usethiscommandtosetthemaximumnumberoflogonattemptsallowedbeforetransitioning
thePWAporttoaheldstate.
Syntax
set pwa maxrequests requests [port-string]
Parameters
Defaults
Ifportstringisnotspecified,maximumrequestswillbesetforallports.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetthePWAmaximumrequeststo3forallports:
B2(su)->set pwa maxrequests 3
set pwa portcontrol
ThiscommandenablesordisablesPWAauthenticati ononselectports.
Syntax
set pwa portcontrol {enable | disable} [port-string]
maxrequests Specifiesthemaximumnumberoflogonattempts.
portstring (Optional)Setsthemaximumrequestsforspecificport(s).Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 72.