Enterasys Enterasys SecureStack B2 B2G124-24 Specifiche Pagina 281

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 600
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 280
set spantree adminedge
SecureStack B2 Configuration Guide 9-39
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaytheedgeportstatusforfe.3.2:
B2(su)->show spantree adminedge port fe.3.2
Port
fe.3.2 has a Port Admin Edge of Edge-Port
set spantree adminedge
UsethiscommandtosettheedgeportadministrativestatusonaSpanningTreeport.
Syntax
set spantree adminedge port-string {true | false}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
Thedefaultbehavioroftheedgeportadministrativestatusbeginswiththevaluesettofalse
initiallyafterthedeviceispoweredup.IfaSpanningTreeBDPUisnotreceivedontheportwithin
afewseconds,thestatussettingchangestotrue.
Example
Thisexampleshowshowtosetfe.1.11asanedgeport:
B2(su)->set spantree adminedge fe.1.11 true
clear spantree adminedge
UsethiscommandtoresetaSpanningTreeporttononedgestatus.
Syntax
clear spantree adminedge port-string
portstring Specifiestheedgeport.Foradetaileddescriptionofpossibleportstring
values,refertoPortStringSyntaxUsedintheCLIonpage 72.
true|false Enables(true)ordisables(false)thespecifiedportasaSpanningTreeedge
port.
Vedere la pagina 280
1 2 ... 276 277 278 279 280 281 282 283 284 285 286 ... 599 600

Commenti su questo manuale

Nessun commento