set port inlinepower
SecureStack B2 Configuration Guide 5-5
B2(su)->show port inlinepower fe.2.1
Port Type Admin Oper Priority Class Power(W)
---- ---- ----- ---- -------- ----- --------
fe.2.1 wireless auto searching low 0 15.4
set port inlinepower
UsethiscommandtoconfigurePoEparametersononeormoreports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoenablePoEonportfe.3.1withcriticalpriority:
B2(su)->set port inlinepower fe.3.1 admin auto priority critical
portstring Specifiestheport(s)onwhichtoconfigurePoE.
adminoff|auto SetsthePoEadministrativestatetooff(disabled)orauto(on).
prioritycritical|
high|low
Setstheport(s)priorityfor thePoEallocationalgorithmtocritical
(highest),highorlow.
typetype Specifiesastringdescribingthetype
ofdeviceconnectedtoaport.