show spantree spanguardtimeout
SecureStack B2 Configuration Guide 9-27
show spantree spanguardtimeout
UsethiscommandtodisplaytheSpanningTreeSpanGuardtimeou tsetting.
Syntax
show spantree spanguardtimeout
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaytheSpanGuardtimeoutsetting:
B2(su)->show spantree spanguardtimeout
Spanguard timeout: 300
set spantree spanguardtimeout
Usethiscommandtosettheamountoftime(inseconds)anedgeportwillremainlockedbythe
SpanGuardfunction.
Syntax
set spantree spanguardtimeout timeout
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosettheSpanGuardtimeoutto600seconds:
B2(su)->set spantree spanguardtimeout 600
timeout Specifiesatimeoutvalueinseconds.Validvaluesare0to65535.
Avalueof0willkeeptheportlockeduntilmanuallyunlocked.Thedefault
valueis300seconds.