show spantree vlanlist
SecureStack B2 Configuration Guide 9-15
B2(su)->clear spantree mstmap 2
show spantree vlanlist
UsethiscommandtodisplaytheSpanningTreeID(s)assignedtooneormoreVLANs.
Syntax
show spantree vlanlist [vlan-list]
Parameters
Defaults
Ifnotspecified,SIDassignmentwillbedisplayedforallVLANs.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaytheSIDsmappedtoVLAN1.Inthiscase,SIDs2,16and42
aremappedtoVLAN1.Forthisinformationtodisplay,theSIDinstancemustbecreated usingthe
setspantreemsticommandasdescribedinsetspantreemstionpage 9
12,andtheFIDsmust
bemappedtoSID 1usingthesetspantreemstmapcommandasdescribedinsetspantree
mstmaponpage 914:
B2(su)->show spantree vlanlist 1
The following SIDS are assigned to VLAN 1: 2 16 42
show spantree mstcfgid
UsethiscommandtodisplaytheMSTconfigurationidentifierelements,includingformatselector,
configurationname,revisionlevel,andconfigurationdigest.
Syntax
show spantree mstcfgid
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaytheMSTconfigurationidentifierelements.Inthiscase,the
defaultrevisionlevelof0,andthedefaultconfigurationname(astringrepresentingthebridge
vlanlist (Optional)DisplaysSIDsassignedtospecificVLAN(s).