set lldp tx-interval
6-22 Discovery Protocol Configuration
set lldp tx-interval
Usethiscommandtosetthetime,inseconds,betweensuccessiveLLDPframetransmissions
initiatedbychangesintheLLDPlocalsysteminformation.
Syntax
set lldp tx-interval frequency
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexamplesetsthetransmitintervalto20seconds.
B2(rw)->set lldp tx-interval 20
set lldp hold-multiplier
UsethiscommandtosetthetimetolivevalueusedinLLDPframessentbythisdevice.Thetime
toliveforLLDPDUdataiscalculatedbymultiplyingthetransmitintervalbytheholdmultiplier
value.
Syntax
set lldp hold-multiplier multiplier-val
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexamplesetsthetransmitintervalto20secondsandtheholdmultiplierto5,whichwill
configureatimetoliveof100tobeusedintheTTL fieldintheLLDPDUheader.
B2(rw)->set lldp tx-interval 20
B2(rw)->set lldp hold-multiplier 5
frequency SpecifiesthenumberofsecondsbetweentransmissionsofLLDP
frames.Valuecanrangefrom5to32,768seconds.Thedefaultis30
seconds.
multiplierval Sp ecifiesthemultipliertoapplytothetransmitintervaltodetermine
thetimetolivevalue.Valuecanrangefrom2to10.Defaultvalueis4.