Startup and General Configuration Summary
General Configuration Command Set
2-24 SecureStack B2 Configuration Guide
2.1.10.8 set switch movemanagement
Use this command to move management switch functionality from one switch to another.
set switch movemanagement fromunit tounit
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to move management functionality from switch 1 to switch 2:
fromunit Specifies the unit number of the current management
switch.
tounit Specifies the unit number of the newly-designated
management switch.
B2(rw)->set switch movemenagement 1 2
Moving stack management will unconfigure entire stack including all interfaces.
Are you sure you want to move stack management? (y/n) y