Spanning Tree Configuration Command Set
Reviewing and Setting Spanning Tree Bridge Parameters
SecureStack B2 Configuration Guide 5-27
5.2.1.21 clear spantree maxage
Use this command to reset the maximum aging time for a Spanning Tree to the default value of 20
seconds.
clear spantree maxage
Syntax Description
None.
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to globally reset the maximum aging time:
B2(rw)->clear spantree maxage