Startup and General Configuration Summary
General Configuration Command Set
2-18 SecureStack B2 Configuration Guide
This example shows how to display information for switch unit 1 in the stack:
This example shows how to display status information for switch unit 1 in the stack:
B2(rw)->show switch 1
Switch............................ 1
Management Status................. Management Switch
Hardware Management Preference.... Unassigned
Admin Management Preference....... Unassigned
Switch Type....................... 0x56950200
Preconfigured Model Identifier.... B2G124-24
Plugged-in Model Identifier....... B2G124-24
Switch Status..................... OK
Switch Description................ Enterasys Networks, Inc. SecureStackB2 --
Model B2G124-24
Detected Code Version............. 01.00.25
Detected Code in Flash............ 01.00.25
Up Time........................... 6 days 0 hrs 40 mins 48 secs
B2(rw)->show switch status 1
Admin Power Configured Card
Switch Status State State Model ID
------ ------ ------- ------- --------------------------------
1 Full Enable Enable B2G124-24
Vedere la pagina 47