Enterasys Enterasys SecureStack B2 B2G124-24 Specifiche Pagina 315

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 488
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 314
VLAN Configuration Command Set
Assigning Port VLAN IDs (PVIDs) and Ingress Filtering
SecureStack B2 Configuration Guide 6-19
6.3.3.7 set port discard
Use this command to set the frame discard mode on one or more ports.
set port discard port-string {untagged | none}
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to set fe.2.7 to discard both tagged and untagged frames:
port-string Specifies the port(s) for which to set frame discard mode.
For a detailed description of possible port-string values,
refer to Section 3.1.1.
untagged | both Sets the port(s) to discard untagged frames or both types of
frames.
B2(rw)->set port discard fe.2.7 both
Vedere la pagina 314
1 2 ... 310 311 312 313 314 315 316 317 318 319 320 ... 487 488

Commenti su questo manuale

Nessun commento