VLAN Configuration Command Set
Assigning Port VLAN IDs (PVIDs) and Ingress Filtering
SecureStack A2 Configuration Guide 6-19
6.3.3.8 clear port discard
Use this command to reset the frame discard mode to the factory default setting (none).
clear port discard port-string
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to reset fe.2.7 to the default discard mode of “none”:
port-string Specifies the port(s) for which to reset frame discard mode.
For a detailed description of possible port-string values,
refer to Section 3.1.1.
A2(rw)->clear port discard fe.2.7