Startup and General Configuration Summary
Configuring CDP
SecureStack A2 Configuration Guide 2-115
Table 2-7 show cdp Output Details
Output What It Displays...
CDP Global Status Whether CDP is globally auto-enabled, enabled or disabled. The
default state of auto-enabled can be reset with the set cdp state
command. For details, refer to Section 2.1.17.2.
CDP Versions
Supported
CDP version number(s) supported by the switch.
CDP Hold Time Minimum time interval (in seconds) at which CDP configuration
messages can be set. The default of 180 seconds can be reset with
the set cdp hold-time command. For details, refer to
Section 2.1.17.5.
CDP Authentication
Code
Authentication code for CDP discovery protocol. The default of
00-00-00-00-00-00-00-00 can be reset using the set cdp auth
command. For details, refer to Section 2.1.17.3.
CDP Transmit
Frequency
Frequency (in seconds) at which CDP messages can be
transmitted. The default of 60 seconds can be reset with the set
cdp interval command. For details, refer to Section 2.1.17.4.
Port Port designation. For a detailed description of possible port-string
values, refer to Section 3.1.1.
Status Whether CDP is enabled, disabled or auto-enabled on the port.