DFE-Gold Module Shutdown Procedure
4-8 Troubleshooting
WhenacontrolledshutdownisinitiatedfromtheOFFLINE/RESET switch,youhave60
secondsfromthetimetheCPUstartsalternatelyflashingamber/offuntilthedevice
automaticallyrestarts.
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch
ToresetaDFEGoldmodulewithoutitperforminganorderlyshutdownroutine,
pressandholdthe OFFLINE/RESETswitchforapproximately6seconds.
RemovinganyDFEGoldmodulefromthechassisbeforeithasbeenshutdownisnot
recommended.Theonlysafetimetoremovea module fromthechassisis
afterthe
completionofashutdownandthemanagementLEDisalternatelyflashingamber/off.
Note: The only safe time to remove a DFE-Gold module from the chassis is when the
CPU LED is alternately flashing amber/off. Otherwise, system operation will be
interrupted.
Caution: This method of shutting down a DFE module is not recommended except as a
last resort, because all processes currently running on the module will be interrupted,
resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos DFE.
Recurra a él sólo como último recurso, puesto que interrumpe todos los procesos del
módulo en funcionamiento, lo que podría resultar pérdidas de frames.