Enterasys Xpedition 2000 Getting Started Guide 41
Installing the Hardware
Figure 24 shows the pin positions in the 50-pin HSSI connector.
Figure 24. 50-pin HSSI connector
The Enterasys Dual HSSI line card uses standard copper twisted-pair cable with identical
50-pin HSSI connectors at each end to attach to a CSU/DSU module.
To attach the segment cables to your Dual HSSI line card:
1. Obtain a Enterasys 50-pin HSSI connector cable (part number SYS-HSSI-CAB) and
connect either end of the HSSI connector cable to the XP WAN interface you wish to
use.
2. Plug the remote end of the connector cable into the HSSI CSU/DSU data port you
wish to use.