Installing Optional 5PIMs
3-4
3.2.1 Removing the Coverplate
Refer to Figure 3-1 and proceed as follows:
1. Attach the antistatic wrist strap (refer to the instructions on the antistatic wrist strap package).
2. Place the module
➀ on an antistatic pad on a sturdy flat surface.
Figure 3-1 Removing the Coverplate
3. Remove the two screws ➁ fastening the coverplate ➂ to the module front panel ➃. Save the
two screws for installing the 5PIM.
4. Remove the screw ➄ fastening the board to the module chassis. Save the screw for installing
the 5PIM.
➀
Module
➂
Coverplate
➄
Fastening screw
➁
Coverplate screws (2)
➃
Module front panel
Ä
À
Á
Â
Ã
36771_13