Installing the Redundant Power System
XSR Getting Started Guide 2-13
Figure 2-18 Redundant Power System
Up to four power systems can be installed in the 1U Passive Power Chassis, as shown in
Figure 2-19, which can be rack mounted. Two-foot long DC power harnesses are provided to
attach XSRs and the chassis, as well as a standard, 2-meter shielded power cord for the chassis-to-
wall outlet connection. Power systems are hot swappable and are equipped with a built-in fan
which extends the units’ lifespans but are not essential for normal functionality.
Figure 2-19 Passive Power Chassis (Fully Loaded)
To install the Redundant Power System in the Passive Power Chassis, perform the following steps:
1. On a clean, static-free surface, insert the power system in the power chassis as shown in
Figure 2-20.
BUPS_06